How Solar System Sizing Works (From Utility Bill to Panel Count)
Sizing a rooftop or ground-mount solar array starts with energy consumed over a full day rather than instantaneous appliance power. Your electric bill lists monthly kilowatt-hours (kWh), while solar contractors quote system sizes in kilowatts DC (kW). Bridging those two numbers requires two critical local factors: Peak Sun Hours and real-world derate efficiency.
Required DC Size (kW) = (Monthly kWh × Target Offset % ÷ 30) ÷ (Peak Sun Hours × System Efficiency)Panel Count = Roundup[(Required DC Size × 1,000) ÷ Individual Panel Wattage]
Suppose your home consumes 950 kWh per month (about 31.7 kWh/day) and sits in a region averaging 4.5 Peak Sun Hours/day. If you apply a realistic 80% (0.80) system efficiency, you divide 31.7 ÷ (4.5 × 0.80) = 8.80 kW DC. Dividing 8,800 watts by 400W solar panels gives 22 panels.
Peak Sun Hours by Region (Avoid the Daylight Trap)
New solar buyers frequently look outside, count 12 hours of summer daylight, and divide their daily kWh by 12. That under-sizes an array by more than half. One Peak Sun Hour is defined as 1,000 W/m² of solar irradiance—effectively noon-level sunshine. Morning, late-afternoon, and winter sun deliver only a fraction of peak intensity.
| Climate / Region Example | Annual Avg Peak Sun Hours | DC kW Needed per 1,000 kWh/mo | 400W Panels Needed |
|---|---|---|---|
| Desert Southwest (Phoenix, Tucson, Las Vegas) | 5.8 – 6.5 hrs/day | ~6.7 – 7.2 kW | 17 – 18 panels |
| Sunny Coastal / South (Los Angeles, Austin, Tampa) | 5.0 – 5.6 hrs/day | ~7.4 – 8.3 kW | 19 – 21 panels |
| Temperate / East & Midwest (Chicago, Atlanta, NY) | 4.0 – 4.7 hrs/day | ~8.9 – 10.4 kW | 23 – 26 panels |
| Cloudy Northern / UK / Pacific NW (Seattle, London) | 3.0 – 3.7 hrs/day | ~11.3 – 13.9 kW | 29 – 35 panels |
Why 80% Efficiency? Inside the System Derate Factor
A 400W solar panel rarely outputs 400 watts on a warm roof. Nameplate STC wattage is measured in a flash chamber at 77°F (25°C) cell temperature. On an 85°F summer afternoon, dark silicon cells climb past 130°F–145°F, trimming power by 10% to 14% immediately. Combined with inverter conversion (~96%–97%), wire resistance (~2%), soiling/dust (~2%), and minor mismatch, total net AC output sits near 78% to 84%.
DC-to-AC Ratio & Roof Layout Setbacks
Notice that an 8.80 kW DC array pairs cleanly with a 7.6 kW AC string or hybrid inverter (a ~1.16 DC:AC ratio). Because panels only hit 100% STC wattage on rare crisp spring days around solar noon, sizing the inverter slightly smaller than panel DC capacity reduces hardware cost and improves morning/cloudy conversion efficiency without meaningful clipping loss.